A Simulation-Based Evaluation of an Intelligent Self-Cooling Personal Protective Equipment System for Firefighters in Zimbabwe
Authors
Industrial and Mechatronics Engineering, University of Zimbabwe, Zimbabwe (Zimbabwe)
Industrial and Mechatronics Engineering, University of Zimbabwe, Zimbabwe (Zimbabwe)
Industrial Electronics Engineering, Chinhoyi University of Technology, Zimbabwe (Zimbabwe)
Article Information
DOI: 10.51583/IJLTEMAS.2026.151000119
Subject Category: Design
Volume/Issue: 15/10 | Page No: 1480-1487
Publication Timeline
Submitted: 2026-10-26
Accepted: 2026-10-31
Published: 2026-11-17
Abstract
Firefighters operating in hot-climate regions such as Zimbabwe experience severe physiological heat strain because conventional multilayer turnout gear restricts evaporative and convective heat loss while providing no integrated thermoregulation.This paper presents the conceptual design, initial theoretical proof of concept, and preliminary economic analysis of an intelligent, self-cooling personal protective equipment (PPE)system architecture developed for resource-constrained fire services.Using a design-based engineering methodology informed by field observations, interviews, and a 40-respondent survey at two Bulawayo fire stations, a hybrid low-cost framework was selected from three candidates through a weighted decision matrix.
The proposed architecture conceptually integrates an STM32L4 microcontroller, MAX30205 and MAX30102 physiological sensors, a five-state finite state machine controller, and a hybrid thermal management subsystem combining active micro-ventilation (~50 W convective, 5.2 L/s flow rate) with passive phase-change material (PCM) buffering (~30 W conductive heat flux), targeting a theoretical cooling capacity of approximately 80 W. Three-zone conjugate-heat-transfer computational fluid dynamics (CFD) modelling and transient MATLAB/Simulink thermal-electrical process simulations were used to evaluate the conceptual feasibility of the system layout in place of physical prototyping.Computational results demonstrate the theoretical viability of the forced-convection cooling pathway, showing a stable fan-driven pressure gradient and an analytical 4.8-minute (25.0%) extension in the baseline time required to reach the 39°C critical core-temperature threshold defined by NFPA 1584 (increasing from an uncooled baseline of 19.16 minutes to 23.95 minutes under a simulated 400 W metabolic load). Process modeling also suggests a theoretical cycle-averaged battery endurance exceeding eight hours. Preliminary economic modeling indicates a projected batch production cost of USD 260 per unit, with 43.8% of structural components sourceable regionally. These findings provide baseline computational performance estimates that establish the technical plausibility and architectural logic of a locally adapted,intelligent PPE concept prior to physical development
Keywords
Computational fluid dynamics, Firefighter personal protective equipment, Heat stress,Hybrid thermal management,Phase-change materials, Physiological monitoring, Wearable sensing systems.
This article is licensed under a Creative Commons Attribution 4.0 International License (CC BY 4.0).
Downloads
References
1. Aljaroudi, A.M. (2021) ’Evaluation of cooling strategies for reducing heat strain in firefighters’, Applied Ergonomics, 92, pp. 1–9. [Google Scholar] [Crossref]
2. Cadarette, B.S., Cheuvront, S.N. and Kolka, M.A. (2002) ’Cooling garments: Efficacy and physiological limitations’, Journal of Applied Physiology, 93(3), pp. 771–778. [Google Scholar] [Crossref]
3. Chikozho, C. (2021) ’Urban emergency management challenges in Zimbabwe’, Journal of African Safety Studies, 9(2), pp. 45–58. [Google Scholar] [Crossref]
4. Chirisa, I., Bandauko, E. and Mazhindu, E. (2021) ’Public safety infrastructure constraints in Zimbabwean cities’, Development Southern Africa, 38(5), pp. 701–718. [Google Scholar] [Crossref]
5. Eisenberg, J. (2019) ’Heat-related illness in emergency responders’, Occupational Medicine, 69(5), pp. 321–328. [Google Scholar] [Crossref]
6. Gagnon, D., Reardon, F.D. and Kenny, G.P. (2010) ’Core temperature thresholds for initiating cooling’, Journal of Applied Physiology, 108(4), pp. 813–821. [Google Scholar] [Crossref]
7. Gao, Y., Wang, L. and Zhang, Y. (2019) ’Smart textiles for firefighter protective clothing’, Advanced Materials Technologies, 4(9), pp. 1–15. [Google Scholar] [Crossref]
8. Giesbrecht, G.G., Jamieson, C. and Cahill, F. (2007) ’Cooling interventions for firefighters’, Journal of Occupational Medicine, 49(4), pp. 380–387. [Google Scholar] [Crossref]
9. Havenith, G. (1999) ’Heat balance when wearing protective clothing’, Annals of Occupational Hygiene, 43(5), pp. 289–296. [Google Scholar] [Crossref]
10. Hostler, D. (2012) ’Firefighter rehabilitation and cooling strategies’, Prehospital Emergency Care, 16(2), pp. 233–241. [Google Scholar] [Crossref]
11. ISO (2017) ISO 7243: Ergonomics of the thermal environment – Assessment of heat stress. Geneva: International Organization for Standardization. [Google Scholar] [Crossref]
12. ISO (2022) ISO 23616: Protective clothing for firefighters – Requirements and test methods. Geneva: International Organization for Standardization. [Google Scholar] [Crossref]
13. Kales, S.N., Soteriades, E.S. and Christophi, C.A. (2007) ’Emergency duties and deaths from heart disease’, New England Journal of Medicine, 356(12), pp. 1207–1215. [Google Scholar] [Crossref]
14. Kaur, G., Singh, R. and Singh, S. (2021) ’Wearable physiological sensors for occupational safety’, IEEE Sensors Journal, 21(9), [Google Scholar] [Crossref]
15. pp. 10421–10432. [Google Scholar] [Crossref]
16. Kuklane, K. (2009) ’Cooling garments in industrial work’, Industrial Health, 47(2), pp. 153–158. [Google Scholar] [Crossref]
17. Lee, J., Kim, S. and Lee, Y. (2014) ’Evaluation of cooling vest performance’, Applied Ergonomics, 45(3), pp. 478–485. [Google Scholar] [Crossref]
18. Madziva, R. (2024) ’Occupational health and safety challenges in Zimbabwe’, African Journal of Safety Management, 6(1), pp. 12–25. [Google Scholar] [Crossref]
19. McLellan, T.M. and Selkirk, G.A. (2004) ’Heat stress while wearing firefighting protective clothing’, Journal of Occupational and Environmental Hygiene, 1(4), pp. 199–208. [Google Scholar] [Crossref]
20. McLellan, T.M. and Selkirk, G.A. (2006) ’The management of heat stress for the firefighter’, Applied Ergonomics, 37(6), pp. 659–666. [Google Scholar] [Crossref]
21. Mondal, S. (2008) ’Phase change materials for smart textiles’, Applied Thermal Engineering, 28(11–12), pp. 1536–1550. [Google Scholar] [Crossref]
22. Mugari, W. (2022) ’Equipment readiness in Zimbabwean municipal fire services’, Journal of African Safety Studies, 10(1), pp. 22–35. [Google Scholar] [Crossref]
23. NFPA (2007) NFPA 1971: Standard on Protective Ensembles for Structural Fire Fighting. Quincy, MA: National Fire Protection Association. [Google Scholar] [Crossref]
24. Norman, D.A. and Stappers, P.J. (2016) ’Design X: Complex sociotechnical systems’, She Ji, 2(2), pp. 83–106. [Google Scholar] [Crossref]
25. Parsons, K. (2014) Human Thermal Environments. 3rd edn. Boca Raton: CRC Press. [Google Scholar] [Crossref]
26. Rossi, R. (2003) Firefighter Clothing and Thermal Environments. Boca Raton: CRC Press. [Google Scholar] [Crossref]
27. Sawka, M.N., Cheuvront, S.N. and Kenefick, R.W. (2011) ’Hypohydration and human performance’, Medicine & Science in Sports & Exercise, 43(8), pp. 153–164. [Google Scholar] [Crossref]
28. Selkirk, G.A., McLellan, T.M. and Wong, J. (2004) ’Active versus passive cooling during firefighter rehabilitation’, Journal of Occupational and Environmental Medicine, 46(6), pp. 587–596. [Google Scholar] [Crossref]
29. Smith, D.L. (2016) ’Firefighter fitness, work capacity, and cardiovascular disease risk’, Journal of Strength and Conditioning Research, 30(1), pp. 1–11. [Google Scholar] [Crossref]
30. Smith, D.L., Manning, T.S. and Petruzzello, S.J. (2005) ’Effect of strenuous live-fire drills’, Ergonomics, 48(11–14), pp. 1403–1415. [Google Scholar] [Crossref]
31. Versteeg, H.K. and Malalasekera, W. (2007) An Introduction to Computational Fluid Dynamics: The Finite Volume Method. 2nd edn. Harlow: Pearson Education. [Google Scholar] [Crossref]
32. Yousefi, A., Nouri, M. and Kazemi, A. (2021) ’AI-based thermal strain prediction models’, Applied Ergonomics, 95, pp. 1–10. [Google Scholar] [Crossref]
33. Zhang, H., Hu, J. and Li, Y. (2016) ’Ventilation cooling in protective clothing’, Textile Research Journal, 86(2), pp. 128–139. [Google Scholar] [Crossref]
34. Zhang, Y., Wang, L. and Gao, Y. (2019) ’Anthropometric considerations in PPE design’, Ergonomics, 62(4), pp. 512–526. [Google Scholar] [Crossref]
This work is licensed under CC BY 4.0