<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.2 20190208//EN"
  "https://jats.nlm.nih.gov/publishing/1.2/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink"
         xmlns:mml="http://www.w3.org/1998/Math/MathML"
         article-type="research-article"
         dtd-version="1.2">

  <!-- ============================================================ FRONT -->
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">IJLTEMAS</journal-id>
      <journal-title-group>
        <journal-title>International Journal of Latest Technology in Engineering, Management &amp; Applied Science (IJLTEMAS)</journal-title>
        <abbrev-journal-title abbrev-type="publisher">IJLTEMAS</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="epub">2278-2540</issn>
      <publisher>
        <publisher-name>IJLTEMAS</publisher-name>
      </publisher>
    </journal-meta>

    <article-meta>
      <!-- IDs -->
      <article-id pub-id-type="publisher-id">717</article-id>
            <article-id pub-id-type="doi">10.51583/IJLTEMAS.2026.151100057</article-id>
      
      <!-- Categories -->
            <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Education</subject>
        </subj-group>
      </article-categories>
      
      <!-- Title -->
      <title-group>
        <article-title>Field Thermal Performance and Modelled Energy Yield of Four 100 W Polycrystalline PV Modules on Different Mounting Substrates in Arusha, Tanzania</article-title>
      </title-group>

      <!-- Authors -->
      <contrib-group>
                <contrib contrib-type="author">
                    <name>
            <surname>John Malima</surname>
            <given-names>Nickson</given-names>
          </name>
                              <aff>
            Electrical Engineering Department, Arusha Technical College, Arusha, Tanzania                        <country>Tanzania</country>
                      </aff>
                    
        </contrib>
                <contrib contrib-type="author">
                    <name>
            <surname>F. Melkior</surname>
            <given-names>Urbanus</given-names>
          </name>
                              <aff>
            Electrical Engineering Department, Arusha Technical College, Arusha, Tanzania                        <country>Tanzania</country>
                      </aff>
                    
        </contrib>
              </contrib-group>

      <!-- Volume / Issue / Pages -->
            <volume>15</volume>
                  <issue>11</issue>
                        <fpage>754</fpage>
            <lpage>772</lpage>
            
      <!-- Dates -->
      <history>
                <date date-type="received">
          <day>09</day>
          <month>11</month>
          <year>2026</year>
        </date>
                        <date date-type="accepted">
          <day>14</day>
          <month>11</month>
          <year>2026</year>
        </date>
              </history>

            <pub-date pub-type="epub">
        <day>26</day>
        <month>11</month>
        <year>2026</year>
      </pub-date>
      
      <!-- DOI Self-URI -->
            <self-uri xlink:href="https://doi.org/10.51583/IJLTEMAS.2026.151100057"/>
      
      <!-- Keywords -->
            <kwd-group kwd-group-type="author">
                <kwd>photovoltaic module temperature; mounting configuration; corrugated metal roof; nominal operating cell temperature; single-diode model; tropical highland climate.</kwd>
              </kwd-group>
      
    </article-meta>
  </front>

  <!-- ============================================================ BODY (Abstract) -->
  <body>
        <sec>
      <title>Abstract</title>
      <p>Photovoltaic (PV) modules in equatorial highland climates operate far above the 25 °C reference of Standard Test Conditions (STC), and the mounting substrate is one of the few variables an installer can still choose after procurement. Four 100 W polycrystalline silicon modules were monitored on four substrates in Arusha, Tanzania (3.4° S, 1 400 m a.s.l.): a bare corrugated metal sheet roof (CMSR), a colour-coated roof sheet, a pole-mounted rack and a concrete slab. Back-surface temperature, ambient conditions and irradiance were logged at 1 min intervals. Under about 1010 W m−2 and 31.2 °C ambient, mean module temperatures were 61.7 °C (CMSR), 59.7 °C (pole), 54.4 °C (coated sheet) and 45.0 °C (concrete, reconstructed by regression). The most robust result, a synchronous paired test, showed the concrete-slab module running 10.3 K cooler than the coated-sheet module (95 % CI 8.9–11.8 K under conservative autocorrelation). Translating temperatures through γ = −0.41 % K−1 gives thermal losses of 15.1, 14.2, 12.1 and 8.2 %, a 7.9 % energy advantage of the slab over the bare roof (8.4 % with a temperature-scaled single-diode model). Field-effective NOCT fell 1.9–16.1 K below declared values. Because each module occupied one substrate, module and mounting effects are partly confounded, and wind speed and electrical output were not measured; the results are therefore presented as strong field evidence that warrants replicated, rotated-assignment trials with anemometry and measured electrical output.</p>
    </sec>
      </body>

  <!-- ============================================================ BACK (References) -->
    <back>
    <ref-list>
      <title>References</title>
            <ref id="ref1">
        <label>1</label>
        <mixed-citation>Adamu, H., Njoka, F., &amp; Kidegho, G. (2024). Performance of MPPT charge controller under moderate- to high-temperature field conditions. Journal of Sustainable Development of Energy, Water and Environment Systems, 12(3), Article 1120504. https://doi.org/10.13044/j.sdewes.d12.0504</mixed-citation>
      </ref>
            <ref id="ref2">
        <label>2</label>
        <mixed-citation>Duffie, J. A., Beckman, W. A., &amp; Blair, N. (2020). Solar engineering of thermal processes, photovoltaics and wind (5th ed.). John Wiley &amp; Sons.</mixed-citation>
      </ref>
            <ref id="ref3">
        <label>3</label>
        <mixed-citation>Dwivedi, P., Sudhakar, K., Soni, A., Solomin, E., &amp; Kirpichnikova, I. (2020). Advanced cooling techniques of P.V. modules: A state of art. Case Studies in Thermal Engineering, 21, Article 100674. https://doi.org/10.1016/j.csite.2020.100674</mixed-citation>
      </ref>
            <ref id="ref4">
        <label>4</label>
        <mixed-citation>Holmgren, W. F., Hansen, C. W., &amp; Mikofski, M. A. (2018). pvlib python: A python package for modeling solar energy systems. Journal of Open Source Software, 3(29), 884.</mixed-citation>
      </ref>
            <ref id="ref5">
        <label>5</label>
        <mixed-citation>https://doi.org/10.21105/joss.00884</mixed-citation>
      </ref>
            <ref id="ref6">
        <label>6</label>
        <mixed-citation>International Electrotechnical Commission. (2016). Photovoltaic (PV) module performance testing and energy rating – Part 2: Spectral responsivity, incidence angle and module operating temperature measurements (IEC 61853-2). IEC.</mixed-citation>
      </ref>
            <ref id="ref7">
        <label>7</label>
        <mixed-citation>International Electrotechnical Commission. (2021a). Photovoltaic devices – Procedures for temperature and irradiance corrections to measured I–V characteristics (IEC 60891, 3rd ed.). IEC.</mixed-citation>
      </ref>
            <ref id="ref8">
        <label>8</label>
        <mixed-citation>International Electrotechnical Commission. (2021b). Photovoltaic system performance – Part 1: Monitoring (IEC 61724-1). IEC.</mixed-citation>
      </ref>
            <ref id="ref9">
        <label>9</label>
        <mixed-citation>International Electrotechnical Commission. (2025). Guidelines for qualifying PV modules, components and materials for operation at high temperatures (IEC TS 63126, 2nd ed.). IEC.</mixed-citation>
      </ref>
            <ref id="ref10">
        <label>10</label>
        <mixed-citation>Kaplanis, S., Kaplani, E., &amp; Kaldellis, J. K. (2022). PV temperature and performance prediction in free-standing, BIPV and BAPV incorporating the effect of temperature and inclination on the heat transfer coefficients and the impact of wind, efficiency and ageing. Renewable Energy, 181, 235–249. https://doi.org/10.1016/j.renene.2021.08.124</mixed-citation>
      </ref>
            <ref id="ref11">
        <label>11</label>
        <mixed-citation>Kempe, M. D., Ovaitt, S., Springer, M., Brown, M., Jordan, D., Sekulic, W., O’Brien, C., Jaubert, J.-N., Yu, Y., Oh, J., TamizhMani, G., &amp; Li, B. (2023). Close roof mounted system temperature estimation for compliance to IEC TS 63126. In Proceedings of the 50th IEEE Photovoltaic Specialists Conference (PVSC). IEEE.</mixed-citation>
      </ref>
            <ref id="ref12">
        <label>12</label>
        <mixed-citation>Kurnia, A. M. (2026). Comparative analysis of temperature coefficients and thermal performance degradation of 50 WP monocrystalline and polycrystalline solar panels using artificial radiation simulation. Asian Journal of Applied Education, 5(2), 367–382.</mixed-citation>
      </ref>
            <ref id="ref13">
        <label>13</label>
        <mixed-citation>https://doi.org/10.55927/ajae.v5i2.16492</mixed-citation>
      </ref>
            <ref id="ref14">
        <label>14</label>
        <mixed-citation>Lazarus, E., Lewis, D. J., Stock, J. H., &amp; Watson, M. W. (2018). HAR inference: Recommendations for practice. Journal of Business &amp; Economic Statistics, 36(4), 541–559.</mixed-citation>
      </ref>
            <ref id="ref15">
        <label>15</label>
        <mixed-citation>https://doi.org/10.1080/07350015.2018.1506926</mixed-citation>
      </ref>
            <ref id="ref16">
        <label>16</label>
        <mixed-citation>Lo Brano, V. (2026). Open and reproducible estimation of PV single-diode parameters from datasheet data. Energy Reports, 15, Article 109280. https://doi.org/10.1016/j.egyr.2026.109280</mixed-citation>
      </ref>
            <ref id="ref17">
        <label>17</label>
        <mixed-citation>Malik, P., Chandel, S. S., &amp; Gupta, R. (2025). A comprehensive review on future research trends in solar cell parameter extraction techniques. Renewable Energy, 251.</mixed-citation>
      </ref>
            <ref id="ref18">
        <label>18</label>
        <mixed-citation>Mlazi, N. J., Mayengo, M., Lyakurwa, G., &amp; Kichonge, B. (2024). Mathematical modeling and extraction of parameters of solar photovoltaic module based on modified Newton–Raphson method. Results in Physics, 57, Article 107364. https://doi.org/10.1016/j.rinp.2024.107364</mixed-citation>
      </ref>
            <ref id="ref19">
        <label>19</label>
        <mixed-citation>Mohamad Radzi, P. N. L., Mekhilef, S., Mohamed Shah, N., Akhter, M. N., Hassani, S., Albaker, A., &amp; Wahyudie, A. (2025). Performance evaluation and degradation analysis of grid connected photovoltaic systems for energy efficient buildings in tropical climates. Scientific Reports, 15, Article 39103. https://doi.org/10.1038/s41598-025-26765-9</mixed-citation>
      </ref>
            <ref id="ref20">
        <label>20</label>
        <mixed-citation>Oezkalay, E., Friesen, G., Caccivio, M., Bonomo, P., Fairbrother, A., Virtuani, A., &amp; Ballif, C. (2022). Operating temperatures and diurnal temperature variations of modules installed in open-rack and typical BIPV configurations. IEEE Journal of Photovoltaics, 12(1), 133–140.</mixed-citation>
      </ref>
            <ref id="ref21">
        <label>21</label>
        <mixed-citation>https://doi.org/10.1109/JPHOTOV.2021.3114988</mixed-citation>
      </ref>
            <ref id="ref22">
        <label>22</label>
        <mixed-citation>Ogbomo, O. O., Amalu, E. H., Ekere, N. N., &amp; Olagbegi, P. O. (2017). A review of photovoltaic module technologies for increased performance in tropical climate. Renewable and Sustainable Energy Reviews, 75, 1225–1238. https://doi.org/10.1016/j.rser.2016.11.109</mixed-citation>
      </ref>
            <ref id="ref23">
        <label>23</label>
        <mixed-citation>Pretorius, J., &amp; Nielsen, S. (2024). Understanding heat dissipation factors for fixed-tilt and single-axis tracked open-rack photovoltaic modules: Experimental insights. Progress in Photovoltaics: Research and Applications. https://doi.org/10.1002/pip.3852</mixed-citation>
      </ref>
            <ref id="ref24">
        <label>24</label>
        <mixed-citation>Prilliman, M., Stein, J. S., Riley, D., &amp; Tamizhmani, G. (2020). Transient weighted moving-average model of photovoltaic module back-surface temperature. IEEE Journal of Photovoltaics, 10(4), 1053–1060. https://doi.org/10.1109/JPHOTOV.2020.2992351</mixed-citation>
      </ref>
            <ref id="ref25">
        <label>25</label>
        <mixed-citation>Rajani, A., Mat Said, D., Ahmad Noorden, Z., Ahmad, N., Arifin, M. S., Atmaja, T. D., Suryaman, N. N., Mustapha, M., Muzhaffar, H. A., Fudholi, A., &amp; Saputra, R. E. (2026). Electrical and thermal performance of double-pass bifacial photovoltaic thermal system in tropical climate. Case Studies in Thermal Engineering, Article 107760. https://doi.org/10.1016/j.csite.2026.107760</mixed-citation>
      </ref>
            <ref id="ref26">
        <label>26</label>
        <mixed-citation>Santiago, I., Trillo-Montero, D., Moreno-Garcia, I. M., Pallarés-López, V., &amp; Luna-Rodríguez, J. J. (2018). Modeling of photovoltaic cell temperature losses: A review and a practice case in South Spain. Renewable and Sustainable Energy Reviews, 90, 70–89. https://doi.org/10.1016/j.rser.2018.03.054</mixed-citation>
      </ref>
            <ref id="ref27">
        <label>27</label>
        <mixed-citation>Smets, A., Jäger, K., Isabella, O., van Swaaij, R., &amp; Zeman, M. (2016). Solar energy: The physics and engineering of photovoltaic conversion technologies and systems. UIT Cambridge.</mixed-citation>
      </ref>
            <ref id="ref28">
        <label>28</label>
        <mixed-citation>Wilks, D. S. (2019). Statistical methods in the atmospheric sciences (4th ed.). Elsevier.</mixed-citation>
      </ref>
            <ref id="ref29">
        <label>29</label>
        <mixed-citation>Yadav, D., Yadav, S. K., Varma, V., Khatoon, S., Singh, J., Singh, R. B., Hasnain, S. M. M., Paramasivam, P., &amp; Tufa, M. A. (2025). Experimental analysis of elevated temperature and soiling loss on the rooftop PV modules performance under composite climatic conditions. Scientific Reports, 15, Article 42035. https://doi.org/10.1038/s41598-025-25846-z</mixed-citation>
      </ref>
          </ref-list>
  </back>
  
</article>