<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.2 20190208//EN"
  "https://jats.nlm.nih.gov/publishing/1.2/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink"
         xmlns:mml="http://www.w3.org/1998/Math/MathML"
         article-type="research-article"
         dtd-version="1.2">

  <!-- ============================================================ FRONT -->
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">IJLTEMAS</journal-id>
      <journal-title-group>
        <journal-title>International Journal of Latest Technology in Engineering, Management &amp; Applied Science (IJLTEMAS)</journal-title>
        <abbrev-journal-title abbrev-type="publisher">IJLTEMAS</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="epub">2278-2540</issn>
      <publisher>
        <publisher-name>IJLTEMAS</publisher-name>
      </publisher>
    </journal-meta>

    <article-meta>
      <!-- IDs -->
      <article-id pub-id-type="publisher-id">719</article-id>
            <article-id pub-id-type="doi">10.51583/IJLTEMAS.2026.151100059</article-id>
      
      <!-- Categories -->
            <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Biomedical Instrumentation</subject>
        </subj-group>
      </article-categories>
      
      <!-- Title -->
      <title-group>
        <article-title>Design and Analysis of an Operational-Amplifier-Based 50 Hz Notch Filter for Biomedical Signal Processing</article-title>
      </title-group>

      <!-- Authors -->
      <contrib-group>
                <contrib contrib-type="author">
                    <name>
            <surname>Ashok Kalange</surname>
            <given-names>Dr.</given-names>
          </name>
                              <aff>
            Department of Physics, Vishwasrao Ransing College (Arts, Commerce and Science), Kalamb–Walchandnagar, Pune, Maharashtra, India                        <country>India</country>
                      </aff>
                    
        </contrib>
              </contrib-group>

      <!-- Volume / Issue / Pages -->
            <volume>15</volume>
                  <issue>11</issue>
                        <fpage>784</fpage>
            <lpage>791</lpage>
            
      <!-- Dates -->
      <history>
                <date date-type="received">
          <day>09</day>
          <month>11</month>
          <year>2026</year>
        </date>
                        <date date-type="accepted">
          <day>14</day>
          <month>11</month>
          <year>2026</year>
        </date>
              </history>

            <pub-date pub-type="epub">
        <day>26</day>
        <month>11</month>
        <year>2026</year>
      </pub-date>
      
      <!-- DOI Self-URI -->
            <self-uri xlink:href="https://doi.org/10.51583/IJLTEMAS.2026.151100059"/>
      
      <!-- Keywords -->
            <kwd-group kwd-group-type="author">
                <kwd>Active notch filter; operational amplifier; twin-T network; 50 Hz interference; ECG; EEG; EMG; biomedical instrumentation; signal conditioning; power-line noise.</kwd>
              </kwd-group>
      
    </article-meta>
  </front>

  <!-- ============================================================ BODY (Abstract) -->
  <body>
        <sec>
      <title>Abstract</title>
      <p>Biomedical signals such as electrocardiograms (ECG), electroencephalograms (EEG), and electromyograms (EMG) are typically low-amplitude signals that are susceptible to power-line interference, electrode noise, and environmental electromagnetic disturbances. In India and many other countries, electrical mains interference occurs at 50 Hz and can obscure important signal characteristics. This paper presents the theoretical design of an active 50 Hz notch filter using an operational amplifier (op-amp) and a twin-T resistor–capacitor network. The proposed circuit is intended to attenuate the unwanted 50 Hz component while allowing frequencies outside the notch region to pass. The notch frequency is determined by the resistor and capacitor values, and the filter response depends on component tolerances, operational-amplifier characteristics, and network loading. A nominal design using 10 kΩ resistors and 320 nF capacitors gives a theoretical notch frequency of approximately 49.7 Hz. The paper discusses circuit implementation, mathematical modelling, component selection, expected performance, and biomedical applications. Simulation and experimental verification are proposed as the next stages of development; no measured performance is claimed in this manuscript. Particular attention is given to preserving diagnostically relevant ECG morphology and ensuring electrical safety in biomedical instrumentation.</p>
    </sec>
      </body>

  <!-- ============================================================ BACK (References) -->
    <back>
    <ref-list>
      <title>References</title>
            <ref id="ref1">
        <label>1</label>
        <mixed-citation>Bansal, D. (2013/2014). “Design of 50 Hz notch filter circuits for better detection of online ECG.” International Journal of Biomedical Engineering and Technology, 13(1), 30–48.</mixed-citation>
      </ref>
            <ref id="ref2">
        <label>2</label>
        <mixed-citation>https://doi.org/10.1504/IJBET.2013.057712</mixed-citation>
      </ref>
            <ref id="ref3">
        <label>3</label>
        <mixed-citation>Naaz, M., Sohel, M. A., Fatima, K., &amp; Raheem, M. A. (2016). “Design of Low Power Notch Filter for Biomedical Applications.” International Journal of Innovative Research in Electrical, Electronics, Instrumentation and Control Engineering. https://doi.org/10.17148/IJIREEICE.2016.41215</mixed-citation>
      </ref>
            <ref id="ref4">
        <label>4</label>
        <mixed-citation>Sohel, M. A., Naaz, M., Raheem, M. A., &amp; Munaaf, M. A. (2017). “Design of discrete time notch filter for biomedical applications.” Proceedings of the 2017 Devices for Integrated Circuit Conference. https://doi.org/10.1109/DEVIC.2017.8073997</mixed-citation>
      </ref>
            <ref id="ref5">
        <label>5</label>
        <mixed-citation>“A portable electrocardiogram for real-time monitoring of cardiac signals.” Discover Applied Sciences (2020). https://link.springer.com/article/10.1007/s42452-020-3065-9</mixed-citation>
      </ref>
            <ref id="ref6">
        <label>6</label>
        <mixed-citation>“The effect of 50/60 Hz notch filter application on human and rat ECG recordings.” (2009). PubMed. https://pubmed.ncbi.nlm.nih.gov/19940344/</mixed-citation>
      </ref>
            <ref id="ref7">
        <label>7</label>
        <mixed-citation>International Electrotechnical Commission. (2011). IEC 60601-2-25: Medical electrical equipment—Particular requirements for the basic safety and essential performance of electrocardiographs. https://webstore.iec.ch/en/publication/2636</mixed-citation>
      </ref>
          </ref-list>
  </back>
  
</article>
