Design and Analysis of an Operational-Amplifier-Based 50 Hz Notch Filter for Biomedical Signal Processing
Authors
Department of Physics, Vishwasrao Ransing College (Arts, Commerce and Science), Kalamb–Walchandnagar, Pune, Maharashtra, India (India)
Article Information
DOI: 10.51583/IJLTEMAS.2026.151100059
Subject Category: Biomedical Instrumentation
Volume/Issue: 15/11 | Page No: 784-791
Publication Timeline
Submitted: 2026-11-09
Accepted: 2026-11-14
Published: 2026-11-26
Abstract
Biomedical signals such as electrocardiograms (ECG), electroencephalograms (EEG), and electromyograms (EMG) are typically low-amplitude signals that are susceptible to power-line interference, electrode noise, and environmental electromagnetic disturbances. In India and many other countries, electrical mains interference occurs at 50 Hz and can obscure important signal characteristics. This paper presents the theoretical design of an active 50 Hz notch filter using an operational amplifier (op-amp) and a twin-T resistor–capacitor network. The proposed circuit is intended to attenuate the unwanted 50 Hz component while allowing frequencies outside the notch region to pass. The notch frequency is determined by the resistor and capacitor values, and the filter response depends on component tolerances, operational-amplifier characteristics, and network loading. A nominal design using 10 kΩ resistors and 320 nF capacitors gives a theoretical notch frequency of approximately 49.7 Hz. The paper discusses circuit implementation, mathematical modelling, component selection, expected performance, and biomedical applications. Simulation and experimental verification are proposed as the next stages of development; no measured performance is claimed in this manuscript. Particular attention is given to preserving diagnostically relevant ECG morphology and ensuring electrical safety in biomedical instrumentation.
Keywords
Active notch filter; operational amplifier; twin-T network; 50 Hz interference; ECG; EEG; EMG; biomedical instrumentation; signal conditioning; power-line noise.
This article is licensed under a Creative Commons Attribution 4.0 International License (CC BY 4.0).
Downloads
References
1. Bansal, D. (2013/2014). “Design of 50 Hz notch filter circuits for better detection of online ECG.” International Journal of Biomedical Engineering and Technology, 13(1), 30–48. [Google Scholar] [Crossref]
2. https://doi.org/10.1504/IJBET.2013.057712 [Google Scholar] [Crossref]
3. Naaz, M., Sohel, M. A., Fatima, K., & Raheem, M. A. (2016). “Design of Low Power Notch Filter for Biomedical Applications.” International Journal of Innovative Research in Electrical, Electronics, Instrumentation and Control Engineering. https://doi.org/10.17148/IJIREEICE.2016.41215 [Google Scholar] [Crossref]
4. Sohel, M. A., Naaz, M., Raheem, M. A., & Munaaf, M. A. (2017). “Design of discrete time notch filter for biomedical applications.” Proceedings of the 2017 Devices for Integrated Circuit Conference. https://doi.org/10.1109/DEVIC.2017.8073997 [Google Scholar] [Crossref]
5. “A portable electrocardiogram for real-time monitoring of cardiac signals.” Discover Applied Sciences (2020). https://link.springer.com/article/10.1007/s42452-020-3065-9 [Google Scholar] [Crossref]
6. “The effect of 50/60 Hz notch filter application on human and rat ECG recordings.” (2009). PubMed. https://pubmed.ncbi.nlm.nih.gov/19940344/ [Google Scholar] [Crossref]
7. International Electrotechnical Commission. (2011). IEC 60601-2-25: Medical electrical equipment—Particular requirements for the basic safety and essential performance of electrocardiographs. https://webstore.iec.ch/en/publication/2636 [Google Scholar] [Crossref]
This work is licensed under CC BY 4.0