Field Thermal Performance and Modelled Energy Yield of Four 100 W Polycrystalline PV Modules on Different Mounting Substrates in Arusha, Tanzania | IJLTEMAS
00
Days
00
Hrs
00
Min
00
Sec
Submit Your Paper

Field Thermal Performance and Modelled Energy Yield of Four 100 W Polycrystalline PV Modules on Different Mounting Substrates in Arusha, Tanzania

Authors

Nickson John Malima

Electrical Engineering Department, Arusha Technical College, Arusha, Tanzania (Tanzania)

Urbanus F. Melkior

Electrical Engineering Department, Arusha Technical College, Arusha, Tanzania (Tanzania)

Article Information

DOI: 10.51583/IJLTEMAS.2026.151100057

Subject Category: Education

Volume/Issue: 15/11 | Page No: 754-772

Publication Timeline

Submitted: 2026-11-09

Accepted: 2026-11-14

Published: 2026-11-26

Abstract

Photovoltaic (PV) modules in equatorial highland climates operate far above the 25 °C reference of Standard Test Conditions (STC), and the mounting substrate is one of the few variables an installer can still choose after procurement. Four 100 W polycrystalline silicon modules were monitored on four substrates in Arusha, Tanzania (3.4° S, 1 400 m a.s.l.): a bare corrugated metal sheet roof (CMSR), a colour-coated roof sheet, a pole-mounted rack and a concrete slab. Back-surface temperature, ambient conditions and irradiance were logged at 1 min intervals. Under about 1010 W m−2 and 31.2 °C ambient, mean module temperatures were 61.7 °C (CMSR), 59.7 °C (pole), 54.4 °C (coated sheet) and 45.0 °C (concrete, reconstructed by regression). The most robust result, a synchronous paired test, showed the concrete-slab module running 10.3 K cooler than the coated-sheet module (95 % CI 8.9–11.8 K under conservative autocorrelation). Translating temperatures through γ = −0.41 % K−1 gives thermal losses of 15.1, 14.2, 12.1 and 8.2 %, a 7.9 % energy advantage of the slab over the bare roof (8.4 % with a temperature-scaled single-diode model). Field-effective NOCT fell 1.9–16.1 K below declared values. Because each module occupied one substrate, module and mounting effects are partly confounded, and wind speed and electrical output were not measured; the results are therefore presented as strong field evidence that warrants replicated, rotated-assignment trials with anemometry and measured electrical output.

Keywords

photovoltaic module temperature; mounting configuration; corrugated metal roof; nominal operating cell temperature; single-diode model; tropical highland climate.

Downloads

References

1. Adamu, H., Njoka, F., & Kidegho, G. (2024). Performance of MPPT charge controller under moderate- to high-temperature field conditions. Journal of Sustainable Development of Energy, Water and Environment Systems, 12(3), Article 1120504. https://doi.org/10.13044/j.sdewes.d12.0504 [Google Scholar] [Crossref]

2. Duffie, J. A., Beckman, W. A., & Blair, N. (2020). Solar engineering of thermal processes, photovoltaics and wind (5th ed.). John Wiley & Sons. [Google Scholar] [Crossref]

3. Dwivedi, P., Sudhakar, K., Soni, A., Solomin, E., & Kirpichnikova, I. (2020). Advanced cooling techniques of P.V. modules: A state of art. Case Studies in Thermal Engineering, 21, Article 100674. https://doi.org/10.1016/j.csite.2020.100674 [Google Scholar] [Crossref]

4. Holmgren, W. F., Hansen, C. W., & Mikofski, M. A. (2018). pvlib python: A python package for modeling solar energy systems. Journal of Open Source Software, 3(29), 884. [Google Scholar] [Crossref]

5. https://doi.org/10.21105/joss.00884 [Google Scholar] [Crossref]

6. International Electrotechnical Commission. (2016). Photovoltaic (PV) module performance testing and energy rating – Part 2: Spectral responsivity, incidence angle and module operating temperature measurements (IEC 61853-2). IEC. [Google Scholar] [Crossref]

7. International Electrotechnical Commission. (2021a). Photovoltaic devices – Procedures for temperature and irradiance corrections to measured I–V characteristics (IEC 60891, 3rd ed.). IEC. [Google Scholar] [Crossref]

8. International Electrotechnical Commission. (2021b). Photovoltaic system performance – Part 1: Monitoring (IEC 61724-1). IEC. [Google Scholar] [Crossref]

9. International Electrotechnical Commission. (2025). Guidelines for qualifying PV modules, components and materials for operation at high temperatures (IEC TS 63126, 2nd ed.). IEC. [Google Scholar] [Crossref]

10. Kaplanis, S., Kaplani, E., & Kaldellis, J. K. (2022). PV temperature and performance prediction in free-standing, BIPV and BAPV incorporating the effect of temperature and inclination on the heat transfer coefficients and the impact of wind, efficiency and ageing. Renewable Energy, 181, 235–249. https://doi.org/10.1016/j.renene.2021.08.124 [Google Scholar] [Crossref]

11. Kempe, M. D., Ovaitt, S., Springer, M., Brown, M., Jordan, D., Sekulic, W., O’Brien, C., Jaubert, J.-N., Yu, Y., Oh, J., TamizhMani, G., & Li, B. (2023). Close roof mounted system temperature estimation for compliance to IEC TS 63126. In Proceedings of the 50th IEEE Photovoltaic Specialists Conference (PVSC). IEEE. [Google Scholar] [Crossref]

12. Kurnia, A. M. (2026). Comparative analysis of temperature coefficients and thermal performance degradation of 50 WP monocrystalline and polycrystalline solar panels using artificial radiation simulation. Asian Journal of Applied Education, 5(2), 367–382. [Google Scholar] [Crossref]

13. https://doi.org/10.55927/ajae.v5i2.16492 [Google Scholar] [Crossref]

14. Lazarus, E., Lewis, D. J., Stock, J. H., & Watson, M. W. (2018). HAR inference: Recommendations for practice. Journal of Business & Economic Statistics, 36(4), 541–559. [Google Scholar] [Crossref]

15. https://doi.org/10.1080/07350015.2018.1506926 [Google Scholar] [Crossref]

16. Lo Brano, V. (2026). Open and reproducible estimation of PV single-diode parameters from datasheet data. Energy Reports, 15, Article 109280. https://doi.org/10.1016/j.egyr.2026.109280 [Google Scholar] [Crossref]

17. Malik, P., Chandel, S. S., & Gupta, R. (2025). A comprehensive review on future research trends in solar cell parameter extraction techniques. Renewable Energy, 251. [Google Scholar] [Crossref]

18. Mlazi, N. J., Mayengo, M., Lyakurwa, G., & Kichonge, B. (2024). Mathematical modeling and extraction of parameters of solar photovoltaic module based on modified Newton–Raphson method. Results in Physics, 57, Article 107364. https://doi.org/10.1016/j.rinp.2024.107364 [Google Scholar] [Crossref]

19. Mohamad Radzi, P. N. L., Mekhilef, S., Mohamed Shah, N., Akhter, M. N., Hassani, S., Albaker, A., & Wahyudie, A. (2025). Performance evaluation and degradation analysis of grid connected photovoltaic systems for energy efficient buildings in tropical climates. Scientific Reports, 15, Article 39103. https://doi.org/10.1038/s41598-025-26765-9 [Google Scholar] [Crossref]

20. Oezkalay, E., Friesen, G., Caccivio, M., Bonomo, P., Fairbrother, A., Virtuani, A., & Ballif, C. (2022). Operating temperatures and diurnal temperature variations of modules installed in open-rack and typical BIPV configurations. IEEE Journal of Photovoltaics, 12(1), 133–140. [Google Scholar] [Crossref]

21. https://doi.org/10.1109/JPHOTOV.2021.3114988 [Google Scholar] [Crossref]

22. Ogbomo, O. O., Amalu, E. H., Ekere, N. N., & Olagbegi, P. O. (2017). A review of photovoltaic module technologies for increased performance in tropical climate. Renewable and Sustainable Energy Reviews, 75, 1225–1238. https://doi.org/10.1016/j.rser.2016.11.109 [Google Scholar] [Crossref]

23. Pretorius, J., & Nielsen, S. (2024). Understanding heat dissipation factors for fixed-tilt and single-axis tracked open-rack photovoltaic modules: Experimental insights. Progress in Photovoltaics: Research and Applications. https://doi.org/10.1002/pip.3852 [Google Scholar] [Crossref]

24. Prilliman, M., Stein, J. S., Riley, D., & Tamizhmani, G. (2020). Transient weighted moving-average model of photovoltaic module back-surface temperature. IEEE Journal of Photovoltaics, 10(4), 1053–1060. https://doi.org/10.1109/JPHOTOV.2020.2992351 [Google Scholar] [Crossref]

25. Rajani, A., Mat Said, D., Ahmad Noorden, Z., Ahmad, N., Arifin, M. S., Atmaja, T. D., Suryaman, N. N., Mustapha, M., Muzhaffar, H. A., Fudholi, A., & Saputra, R. E. (2026). Electrical and thermal performance of double-pass bifacial photovoltaic thermal system in tropical climate. Case Studies in Thermal Engineering, Article 107760. https://doi.org/10.1016/j.csite.2026.107760 [Google Scholar] [Crossref]

26. Santiago, I., Trillo-Montero, D., Moreno-Garcia, I. M., Pallarés-López, V., & Luna-Rodríguez, J. J. (2018). Modeling of photovoltaic cell temperature losses: A review and a practice case in South Spain. Renewable and Sustainable Energy Reviews, 90, 70–89. https://doi.org/10.1016/j.rser.2018.03.054 [Google Scholar] [Crossref]

27. Smets, A., Jäger, K., Isabella, O., van Swaaij, R., & Zeman, M. (2016). Solar energy: The physics and engineering of photovoltaic conversion technologies and systems. UIT Cambridge. [Google Scholar] [Crossref]

28. Wilks, D. S. (2019). Statistical methods in the atmospheric sciences (4th ed.). Elsevier. [Google Scholar] [Crossref]

29. Yadav, D., Yadav, S. K., Varma, V., Khatoon, S., Singh, J., Singh, R. B., Hasnain, S. M. M., Paramasivam, P., & Tufa, M. A. (2025). Experimental analysis of elevated temperature and soiling loss on the rooftop PV modules performance under composite climatic conditions. Scientific Reports, 15, Article 42035. https://doi.org/10.1038/s41598-025-25846-z [Google Scholar] [Crossref]

Metrics

Views & Downloads

Similar Articles

Engineering,
Management &
Applied Science
Journal
(IJLTEMAS)
Published by RSIS International
Tower B, Suncity Success Tower
Golf Course Ext Rd, Sector 65
Gurugram, Haryana 122101, India
© 2026 IJLTEMAS · RSIS International. ISSN 2278-2540.